From 83038976865c7008de266820aacdec9a96f59a17 Mon Sep 17 00:00:00 2001 From: Marcel Holtmann Date: Sun, 29 Jun 2014 13:51:42 +0200 Subject: [PATCH] doc: Move get clock info command to the next available opcode --- doc/mgmt-api.txt | 74 ++++++++++++++++++++++++------------------------ 1 file changed, 37 insertions(+), 37 deletions(-) diff --git a/doc/mgmt-api.txt b/doc/mgmt-api.txt index d329d4a66..3461f7899 100644 --- a/doc/mgmt-api.txt +++ b/doc/mgmt-api.txt @@ -1785,6 +1785,43 @@ Get Connection Information Command Invalid Index +Get Clock Information Command +============================= + + Command Code: 0x0032 + Controller Index: + Command Parameters: Address (6 Octets) + Address_Type (1 Octet) + Return Parameters: Address (6 Octets) + Address_Type (1 Octet) + Local_Clock (4 Octets) + Piconet_Clock (4 Octets) + Accuracy (2 Octets) + + This command is used to get local and piconet clock information. + + Possible values for the Address_Type parameter: + 0 BR/EDR + 1 Reserved (not in use) + 2 Reserved (not in use) + + The Accuracy can be set to 0xffff which means the value is unknown. + + If the Address is set to 00:00:00:00:00:00, then only the + Local_Clock field has a valid value. The Piconet_Clock and + Accuracy fields are invalid and shall be ignored. + + This command generates a Command Complete event on success and + on failure. In case of failure only Address and Address_Type fields + are valid and values of remaining parameters are considered invalid + and shall be ignored. + + Possible errors: Not Connected + Not Powered + Invalid Parameters + Invalid Index + + Load Connection Parameters Command ================================== @@ -1829,43 +1866,6 @@ Load Connection Parameters Command Not Supported -Get Clock Information Command -============================= - - Command Code: 0x0033 - Controller Index: - Command Parameters: Address (6 Octets) - Address_Type (1 Octet) - Return Parameters: Address (6 Octets) - Address_Type (1 Octet) - Local_Clock (4 Octets) - Piconet_Clock (4 Octets) - Accuracy (2 Octets) - - This command is used to get local and piconet clock information. - - Possible values for the Address_Type parameter: - 0 BR/EDR - 1 Reserved (not in use) - 2 Reserved (not in use) - - The Accuracy can be set to 0xffff which means the value is unknown. - - If the Address is set to 00:00:00:00:00:00, then only the - Local_Clock field has a valid value. The Piconet_Clock and - Accuracy fields are invalid and shall be ignored. - - This command generates a Command Complete event on success and - on failure. In case of failure only Address and Address_Type fields - are valid and values of remaining parameters are considered invalid - and shall be ignored. - - Possible errors: Not Connected - Not Powered - Invalid Parameters - Invalid Index - - Command Complete Event ====================== -- 2.47.3