diff --git a/doc/thermometer-api.txt b/doc/thermometer-api.txt
index 5bbd4bf..7b99800 100644
--- a/doc/thermometer-api.txt
+++ b/doc/thermometer-api.txt
EnableIntermediateMeasurement(object agent)
- Enables intermediate measurement notifications for this
- agent. Intermediate measurements will be enabled only
- for thermometers which support it.
+ Enables intermediate measurement notifications
+ for this agent. Intermediate measurements will
+ be enabled only for thermometers which support it.
Possible Errors: org.bluez.Error.InvalidArguments
DisableIntermediateMeasurement(object agent)
- Disables intermediate measurement notifications for this
- agent. It will disable notifications in thermometers
- when the last agent removes the watcher for intermediate
- measurements.
+ Disables intermediate measurement notifications
+ for this agent. It will disable notifications in
+ thermometers when the last agent removes the
+ watcher for intermediate measurements.
Possible Errors: org.bluez.Error.InvalidArguments
org.bluez.Error.NotFound
Properties boolean Intermediate [readonly]
- True if the thermometer supports intermediate measurement
- notifications.
+ True if the thermometer supports intermediate
+ measurement notifications.
uint16 Interval (optional) [readwrite]
- The Measurement Interval defines the time (in seconds)
- between measurements. This interval is not related to
- the intermediate measurements and must be defined into
- a valid range. Setting it to zero means that no periodic
- measurements will be taken.
+ The Measurement Interval defines the time (in
+ seconds) between measurements. This interval is
+ not related to the intermediate measurements and
+ must be defined into a valid range. Setting it
+ to zero means that no periodic measurements will
+ be taken.
uint16 Maximum (optional) [readonly]
Measurement value is calculated as
(Mantissa) * (10^Exponent)
- For special cases Exponent is set to 0
- and Mantissa is set to one of following
- values:
+ For special cases Exponent is
+ set to 0 and Mantissa is set to
+ one of following values:
- +(2^23 - 1) NaN (invalid or missing data)
+ +(2^23 - 1) NaN (invalid or
+ missing data)
-(2^23) NRes
+(2^23 - 2) +Infinity
-(2^23 - 2) -Infinity
string Unit:
- Possible values: "celsius" or "fahrenheit"
+ Possible values: "celsius" or
+ "fahrenheit"
uint64 Time (optional):
- Time of measurement, if supported by device.
+ Time of measurement, if
+ supported by device.
Expressed in seconds since epoch.
string Type (optional):
- Only present if measurement type is known.
+ Only present if measurement type
+ is known.
- Possible values: "armpit", "body", "ear",
- "finger", "intestines", "mouth",
- "rectum", "toe", "tympanum"
+ Possible values: "armpit", "body",
+ "ear", "finger", "intestines",
+ "mouth", "rectum", "toe",
+ "tympanum"
string Measurement:
- Possible values: "final" or "intermediate"
+ Possible values: "final" or
+ "intermediate"